Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Anesthesiology ; 140(3): 430-441, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38064715

RESUMO

BACKGROUND: Exaggerated lung strain and stress could damage lungs in anesthetized children. The authors hypothesized that the association of capnoperitoneum and lung collapse in anesthetized children increases lung strain-stress. Their primary aim was to describe the impact of capnoperitoneum on lung strain-stress and the effects of an individualized protective ventilation during laparoscopic surgery in children. METHODS: The authors performed an observational cohort study in healthy children aged 3 to 7 yr scheduled for laparoscopic surgery in a community hospital. All received standard protective ventilation with 5 cm H2O of positive end-expiratory pressure (PEEP). Children were evaluated before capnoperitoneum, during capnoperitoneum before and after lung recruitment and optimized PEEP (PEEP adjusted to get end-expiratory transpulmonary pressure of 0), and after capnoperitoneum with optimized PEEP. The presence of lung collapse was evaluated by lung ultrasound, positive Air-Test (oxygen saturation measured by pulse oximetry 96% or less breathing 21% O2 for 5 min), and negative end-expiratory transpulmonary pressure. Lung strain was calculated as tidal volume/end-expiratory lung volume measured by capnodynamics, and lung stress as the end-inspiratory transpulmonary pressure. RESULTS: The authors studied 20 children. Before capnoperitoneum, mean lung strain was 0.20 ± 0.07 (95% CI, 0.17 to 0.23), and stress was 5.68 ± 2.83 (95% CI, 4.44 to 6.92) cm H2O. During capnoperitoneum, 18 patients presented lung collapse and strain (0.29 ± 0.13; 95% CI, 0.23 to 0.35; P < 0.001) and stress (5.92 ± 3.18; 95% CI, 4.53 to 7.31 cm H2O; P = 0.374) increased compared to before capnoperitoneum. During capnoperitoneum and optimized PEEP, children presenting lung collapse were recruited and optimized PEEP was 8.3 ± 2.2 (95% CI, 7.3 to 9.3) cm H2O. Strain returned to values before capnoperitoneum (0.20 ± 0.07; 95% CI, 0.17 to 0.22; P = 0.318), but lung stress increased (7.29 ± 2.67; 95% CI, 6.12 to 8.46 cm H2O; P = 0.020). After capnoperitoneum, strain decreased (0.18 ± 0.04; 95% CI, 0.16 to 0.20; P = 0.090), but stress remained higher (7.25 ± 3.01; 95% CI, 5.92 to 8.57 cm H2O; P = 0.024) compared to before capnoperitoneum. CONCLUSIONS: Capnoperitoneum increased lung strain in healthy children undergoing laparoscopy. Lung recruitment and optimized PEEP during capnoperitoneum decreased lung strain but slightly increased lung stress. This little rise in pulmonary stress was maintained within safe, lung-protective, and clinically acceptable limits.


Assuntos
Laparoscopia , Atelectasia Pulmonar , Criança , Humanos , Pulmão , Respiração Artificial , Estudos de Coortes
2.
Paediatr Anaesth ; 34(3): 251-258, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38055609

RESUMO

BACKGROUND: Capnodynamic lung function monitoring generates variables that may be useful for pediatric perioperative ventilation. AIMS: Establish normal values for end-expiratory lung volume CO2 in healthy children undergoing anesthesia and to compare these values to previously published values obtained with alternative end-expiratory lung volume methods. The secondary aim was to investigate the ability of end-expiratory lung volume CO2 to react to positive end-expiratory pressure-induced changes in end-expiratory lung volume. In addition, normal values for associated volumetric capnography lung function variables were examined. METHODS: Fifteen pediatric patients with healthy lungs (median age 8 months, range 1-36 months) undergoing general anesthesia were examined before start of surgery. Tested variables were recorded at baseline positive end-expiratory pressure 3 cmH2 O, 1 and 3 min after positive end-expiratory pressure 10 cmH2 O and 3 min after returning to baseline positive end-expiratory pressure 3 cmH2 O. RESULTS: Baseline end-expiratory lung volume CO2 was 32 mL kg-1 (95% CI 29-34 mL kg-1 ) which increased to 39 mL kg-1 (95% CI 35-43 mL kg-1 , p < .0001) and 37 mL kg-1 (95% CI 34-41 mL kg-1 , p = .0003) 1 and 3 min after positive end-expiratory pressure 10 cmH2 O, respectively. End-expiratory lung volume CO2 returned to baseline, 33 mL kg-1 (95% CI 29-37 mL kg-1 , p = .72) 3 min after re-establishing positive end-expiratory pressure 3 cmH2 O. Airway dead space increased from 1.1 mL kg-1 (95% CI 0.9-1.4 mL kg-1 ) to 1.4 (95% CI 1.1-1.8 mL kg-1 , p = .003) and 1.5 (95% CI 1.1-1.8 mL kg-1 , p < .0001) 1 and 3 min after positive end-expiratory pressure 10 cmH2 O, respectively, and 1.2 mL kg-1 (95% CI 0.9-1.4 mL kg-1 , p = .08) after 3 min of positive end-expiratory pressure 3 cmH2 O. Additional volumetric capnography and lung function variables showed no major changes in response to positive end-expiratory pressure variations. CONCLUSIONS: Capnodynamic noninvasive and continuous end-expiratory lung volume CO2 values assessed during anesthesia in children were in close agreement with previously reported end-expiratory lung volume values generated by alternative methods. Furthermore, positive end-expiratory pressure changes resulted in physiologically expected end-expiratory lung volume CO2 responses in a timely manner, suggesting that it can be used to trend end-expiratory lung volume changes during anesthesia.


Assuntos
Dióxido de Carbono , Respiração , Humanos , Criança , Lactente , Pré-Escolar , Medidas de Volume Pulmonar , Respiração com Pressão Positiva , Pulmão , Anestesia Geral , Volume de Ventilação Pulmonar
3.
J Cardiothorac Vasc Anesth ; 36(8 Pt B): 2900-2907, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35283043

RESUMO

OBJECTIVES: To test the clinical performance of a novel continuous noninvasive cardiac output (CO) monitoring based on expired carbon dioxide kinetics in cardiac surgery patients. DESIGN: A prospective feasibility pragmatic clinical study. SETTING: A single-center, large community hospital. PARTICIPANTS: Thirty-two patients undergoing cardiac surgery were studied during the intraoperative (before cardiopulmonary bypass) and postoperative (in the intensive care unit before extubation) periods. INTERVENTIONS: CO was measured simultaneously by the continuous capnodynamic method and by transpulmonary thermodilution during changes in the patient's hemodynamic and/or respiratory conditions. MEASUREMENTS AND MAIN RESULTS: The current recommended comparative statistics for CO measurement methods were analyzed, including bias, precision, and percentage error obtained from Bland-Altman analysis, and concordance between methods obtained from the four-quadrant plot analysis to evaluate the trending ability. Bias ± limits of agreement and percentage error were -0.6 (-1.9 to +0.8; 95% CI of 3.73-5.25) L/min and 31% (n = 147 measurements) for the intraoperative period, -0.8 (-2.4 to +0.9; 95% CI of 3.03-5.21) L/min and 41% (n = 66) for the postoperative period, and -0.6 (-2.1 to +0.8; 95% CI of 3.74-5.00) L/min and 34% (n = 213) for the pooled data. The trending analysis obtained a concordance of 82% (n = 65) for the intraoperative and 71% (n = 24) for the early postoperative periods. Aggregation of both data sets gave a concordance of 79% (n = 89). CONCLUSIONS: The continuous capnodynamic method was reliable and in good agreement with the reference method, and had an accuracy and trending ability good enough to make it a possible future alternative for hemodynamic monitoring in the studied population of elective adult cardiac surgery patients.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Monitorização Intraoperatória , Adulto , Débito Cardíaco , Procedimentos Cirúrgicos Cardíacos/métodos , Humanos , Monitorização Intraoperatória/métodos , Estudos Prospectivos , Artéria Pulmonar , Reprodutibilidade dos Testes , Termodiluição/métodos
4.
Anesth Analg ; 134(3): 644-652, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34304235

RESUMO

BACKGROUND: The objective of this study was to compare esophageal Doppler cardiac output (COEDM) against the reference method effective pulmonary blood flow cardiac output (COEPBF), for agreement of absolute values and ability to detect change in cardiac output (CO) in pediatric surgical patients. Furthermore, the relationship between these 2 methods and noninvasive blood pressure (NIBP) parameters was evaluated. METHODS: Fifteen children American Society of Anesthesiology (ASA) I and II (median age, 8 months; median weight, 9 kg) scheduled for surgery were investigated in this prospective observational cohort study. Baseline COEPBF/COEDM/NIBP measurements were made at positive end-expiratory pressure (PEEP) 3 cm H2O. PEEP was increased to 10 cm H2O and COEPBF/COEDM/NIBP was recorded after 1 and 3 minutes. PEEP was then lowered to 3 cm H2O, and all measurements were repeated after 3 minutes. Finally, 20-µg kg-1 intravenous atropine was given with the intent to increase CO, and all measurements were recorded again after 5 minutes. Paired recordings of COEDM and COEPBF were examined for agreement and trending ability, and all parameters were analyzed for their responses to the hemodynamic challenges. RESULTS: Bias between COEDM and COEPBF (COEDM - COEPBF) was -17 mL kg-1 min-1 (limits of agreement, -67 to +33 mL kg-1 min-1) with a mean percentage error of 32% (95% confidence interval [CI], 25-37) and a concordance rate of 71% (95% CI, 63-80). The hemodynamic interventions caused by PEEP manipulations resulted in significant decrease in COEPBF absolute numbers (155 mL kg-1 min-1 [95% CI, 151-159] to 127 mL kg-1 min-1 [95% CI, 113-141]) and a corresponding relative decrease of 18% (95% CI, 14-22) 3 minutes after application of PEEP 10. No corresponding decreases were detected by COEDM. Mean arterial pressure showed a relative decrease with 5 (95% CI, 2-8) and 6% (95% CI, 2-10) 1 and 3 minutes after the application of PEEP 10, respectively. Systolic arterial pressure showed a relative decrease of 5% (95% CI, 2-10) 3 minutes after application of PEEP 10. None of the recorded parameters responded to atropine administration except for heart rate that showed a 4% relative increase (95% CI, 1-7, P = .02) 5 minutes after atropine. CONCLUSIONS: COEDM was unable to detect the reduction of CO cause by increased PEEP, whereas COEPBF and to a minimal extent NIBP detected these changes in CO. The ability of COEPBF to react to minor reductions in CO, before noticeable changes in NIBP are seen, suggests that COEPBF may be a potentially useful tool for hemodynamic monitoring in mechanically ventilated children.


Assuntos
Anestesia , Capnografia/métodos , Débito Cardíaco , Esôfago/diagnóstico por imagem , Ultrassonografia Doppler/métodos , Adjuvantes Anestésicos/farmacologia , Pressão Arterial/efeitos dos fármacos , Atropina/farmacologia , Pressão Sanguínea , Pré-Escolar , Estudos de Coortes , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Respiração com Pressão Positiva , Estudos Prospectivos , Reprodutibilidade dos Testes , Respiração Artificial
5.
Anaesth Intensive Care ; 50(4): 281-288, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34871514

RESUMO

In general anaesthesia, early collapse of poorly ventilated lung segments with low alveolar ventilation-perfusion ratios occurs and may lead to postoperative pulmonary complications after abdominal surgery. An 'open lung' ventilation strategy involves lung recruitment followed by 'individualised' positive end-expiratory pressure titrated to maintain recruitment of low alveolar ventilation-perfusion ratio lung segments. There are limited data in laparoscopic surgery on the effects of this on pulmonary gas exchange. Forty laparoscopic bowel surgery patients were randomly assigned to standard ventilation or an 'open lung' ventilation intervention, with end-tidal target sevoflurane of 1% supplemented by propofol infusion. After peritoneal insufflation, stepped lung recruitment was performed in the intervention group followed by maintenance positive end-expiratory pressure of 12-15 cmH2O adjusted to maintain dynamic lung compliance at post-recruitment levels. Baseline gas and blood samples were taken and repeated after a minimum of 30 minutes for oxygen and carbon dioxide and for sevoflurane partial pressures using headspace equilibration. The sevoflurane arterial/alveolar partial pressure ratio and alveolar deadspace fraction were unchanged from baseline and remained similar between groups (mean (standard deviation) control group = 0.754 (0.086) versus intervention group = 0.785 (0.099), P = 0.319), while the arterial oxygen partial pressure/fractional inspired oxygen concentration ratio was significantly higher in the intervention group at the second timepoint (control group median (interquartile range) 288 (234-372) versus 376 (297-470) mmHg in the intervention group, P = 0.011). There was no difference between groups in the sevoflurane consumption rate. The efficiency of sevoflurane uptake is not improved by open lung ventilation in laparoscopy, despite improved arterial oxygenation associated with effective and sustained recruitment of low alveolar ventilation-perfusion ratio lung segments.


Assuntos
Laparoscopia , Troca Gasosa Pulmonar , Humanos , Pulmão , Oxigênio , Respiração Artificial , Sevoflurano
6.
J Clin Monit Comput ; 36(5): 1557-1567, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-34966951

RESUMO

To determine whether end-expiratory lung volume measured with volumetric capnography (EELVCO2) can individualize positive end-expiratory pressure (PEEP) setting during laparoscopic surgery. We studied patients undergoing laparoscopic surgery subjected to Fowler (F-group; n = 20) or Trendelenburg (T-group; n = 20) positions. EELVCO2 was measured at 0° supine (baseline), during capnoperitoneum (CP) at 0° supine, during CP with Fowler (head up + 20°) or Trendelenburg (head down - 30°) positions and after CP back to 0° supine. PEEP was adjusted to preserve baseline EELVCO2 during and after CP. Baseline EELVCO2 was statistically similar to predicted FRC in both groups. At supine and CP, EELVCO2 decreased from baseline values in F-group [median and IQR 2079 (768) to 1545 (725) mL; p = 0.0001] and in T-group [2164 (789) to 1870 (940) mL; p = 0.0001]. Change in body position maintained EELVCO2 unchanged in both groups. PEEP adjustments from 5.6 (1.1) to 10.0 (2.5) cmH2O in the F-group (p = 0.0001) and from 5.6 (0.9) to 10.0 (2.6) cmH2O in T-group (p = 0.0001) were necessary to reach baseline EELVCO2 values. EELVCO2 increased close to baseline with PEEP in the F-group [1984 (600) mL; p = 0.073] and in the T-group [2175 (703) mL; p = 0.167]. After capnoperitoneum and back to 0° supine, PEEP needed to maintain EELVCO2 was similar to baseline PEEP in F-group [5.9 (1.8) cmH2O; p = 0.179] but slightly higher in the T-group [6.5 (2.2) cmH2O; p = 0.006]. Those new PEEP values gave EELVCO2 similar to baseline in the F-group [2039 (980) mL; p = 0.370] and in the T-group [2150 (715) mL; p = 0.881]. Breath-by-breath noninvasive EELVCO2 detected changes in lung volume induced by capnoperitoneum and body position and was useful to individualize the level of PEEP during laparoscopy.Trial registry: Clinicaltrials.gov NCT03693352. Protocol started 1st October 2018.


Assuntos
Dióxido de Carbono , Laparoscopia , Humanos , Pulmão , Medidas de Volume Pulmonar , Respiração com Pressão Positiva/métodos , Respiração
7.
Eur J Anaesthesiol ; 38(12): 1242-1252, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34155171

RESUMO

BACKGROUND: Cardiac output (CO) monitoring is the basis of goal-directed treatment for major abdominal surgery. A capnodynamic method estimating cardiac output (COEPBF) by continuously calculating nonshunted pulmonary blood flow has previously shown good agreement and trending ability when evaluated in mechanically ventilated pigs. OBJECTIVES: To compare the performance of the capnodynamic method of CO monitoring with transpulmonary thermodilution (COTPTD) in patients undergoing major abdominal surgery. DESIGN: Prospective, observational, method comparison study. Simultaneous measurements of COEPBF and COTPTD were performed before incision at baseline and before and after increased (+10 cmH2O) positive end-expiratory pressure (PEEP), activation of epidural anaesthesia and intra-operative events of hypovolemia and low CO. The first 25 patients were ventilated with PEEP 5 cmH2O (PEEP5), while in the last 10 patients, lung recruitment followed by individual PEEP adjustment (PEEPadj) was performed before protocol start. SETTING: Karolinska University Hospital, Stockholm, Sweden. PATIENTS: In total, 35 patients (>18 years) scheduled for major abdominal surgery with advanced hemodynamic monitoring were included in the study. MAIN OUTCOME MEASURES AND ANALYSIS: Agreement and trending ability between COEPBF and COTPTD at different clinical moments were analysed with Bland--Altman and four quadrant plots. RESULTS: In total, 322 paired values, 227 in PEEP5 and 95 in PEEPadj were analysed. Respectively, the mean COEPBF and COTPTD were 4.5 ±â€Š1.0 and 4.8 ±â€Š1.1 in the PEEP5 group and 4.9 ±â€Š1.2 and 5.0 ±â€Š1.0 l min-1 in the PEEPadj group. Mean bias (levels of agreement) and percentage error (PE) were -0.2 (-2.2 to 1.7) l min-1 and 41% for the PEEP5 group and -0.1 (-1.7 to 1.5) l min-1 and 31% in the PEEPadj group. Concordance rates during changes in COEPBF and COTPTD were 92% in the PEEP5 group and 90% in the PEEPadj group. CONCLUSION: COEPBF provides continuous noninvasive CO estimation with acceptable performance, which improved after lung recruitment and PEEP adjustment, although not interchangeable with COTPTD. This method may become a tool for continuous intra-operative CO monitoring during general anaesthesia in the future. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT03444545.


Assuntos
Respiração com Pressão Positiva , Termodiluição , Animais , Débito Cardíaco , Humanos , Monitorização Fisiológica , Estudos Prospectivos , Reprodutibilidade dos Testes , Suínos
8.
Acta Anaesthesiol Scand ; 64(8): 1114-1119, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32386340

RESUMO

BACKGROUND: Capnoperitoneum provides a ventilatory challenge due to reduction in end-expiratory lung volume and peritoneal carbon dioxide absorption in both children and adults. The primary aim of this controlled interventional trial was to determine the positive end-expiratory pressure (PEEP) level needed to ensure for adequate carbon dioxide clearance and preservation of carbon dioxide homeostasis in an experimental model of infant laparoscopy. The secondary aim was to evaluate potential effects on cardiac output of PEEP and abdominal pressure level variations in the same setting. METHODS: Eight chinchilla bastard rabbits were anesthetized and mechanically ventilated. Intra-abdominal pressures were randomly set to 0, 6, and 12 mm Hg by carbon dioxide insufflation. Carbon dioxide clearance using volumetric capnography, arterial blood gas data, and cardiac output was recorded, while PEEP 3, 6, and 9 cmH2 O were applied in a random order. RESULTS: A PEEP of 9 cmH2 O showed restoration of carbon dioxide clearance without causing changes in arterial partial pressure of carbon dioxide and bicarbonate and with no associated deterioration in cardiac output. CONCLUSION: The results promote a PEEP level of 9 cmH2 O in this model of infant capnoperitoneum to allow for adequate carbon dioxide removal with subsequent preservation of carbon dioxide homeostasis. The use of high PEEP was not associated with any decrease in cardiac output.


Assuntos
Dióxido de Carbono/administração & dosagem , Laparoscopia/métodos , Pneumoperitônio/prevenção & controle , Respiração com Pressão Positiva/métodos , Animais , Modelos Animais de Doenças , Homeostase , Insuflação , Pediatria , Coelhos
9.
Acta Anaesthesiol Scand ; 64(8): 1106-1113, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32314349

RESUMO

BACKGROUND: Capnoperitoneum during laparoscopy leads to cranial shift of the diaphragm, loss in lung volume, and risk of impaired gas exchange. Infants are susceptible to these changes and bedside assessment of lung volume during laparoscopy might assist with optimizing the ventilation. Thus, the primary aim was to investigate the monitoring value of a continuous end-expiratory lung volume (EELV) assessment method based on CO2 dynamics ( EELV CO 2 ) in a pediatric capnoperitoneum model by evaluating the correlation and trending ability against helium washout (EELVHe ). METHODS: Intra-abdominal pressure (IAP) was randomly varied between 0, 6, and 12 mm Hg with CO2 insufflation, while positive end-expiratory pressure (PEEP) levels of 3, 6, and 9 cm H2 O were randomly applied in eight anesthetized and mechanically ventilated chinchilla rabbits. Concomitant EELV CO 2 and EELVHe and lung clearance index (LCI) were obtained under each experimental condition. RESULTS: Significant correlations were found between EELV CO 2 and EELVHe before capnoperitoneum (r = .85, P < .001), although increased IAP distorted this relationship. The negative influence of IAP was counteracted by the application of PEEP 9, which restored the correlation between EELV CO 2 and EELVHe and resulted in 100% concordance rate between the methods regarding changes in lung volume. EELVHe and LCI showed a curvilinear relationship, and an EELVHe of approximately 20 mL kg-1 , determined with a receiver operating characteristic curve, was associated with near-normal LCI values. CONCLUSION: In this animal model of pediatric capnoperitoneum, reliable assessment of changes in EELV based on EELV CO 2 requires an open lung strategy, defined as EELV above approximately 20 mL kg-1 .


Assuntos
Dióxido de Carbono/administração & dosagem , Hélio/administração & dosagem , Insuflação/métodos , Cavidade Peritoneal/fisiopatologia , Pneumoperitônio/fisiopatologia , Respiração com Pressão Positiva/métodos , Animais , Modelos Animais de Doenças , Laparoscopia/métodos , Medidas de Volume Pulmonar , Pediatria , Coelhos
10.
Acta Anaesthesiol Scand ; 64(5): 670-676, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31965563

RESUMO

INTRODUCTION: Lung protective ventilation can decrease post-operative pulmonary complications. The aim of this study was to evaluate a capnodynamic method estimating effective lung volume (ELV) as a proxy for end-expiratory lung volume in response to PEEP changes in patients, healthy subjects and a porcine model. METHODS: Agreement and trending ability for ELV in anaesthetized patients and agreement in awake subjects were evaluated using nitrogen multiple breath wash-out/in and plethysmography as a reference respectively. Agreement and trending ability were evaluated in pigs during PEEP elevations with inert gas wash-out as reference. RESULTS: In anaesthetized patients bias (95% limits of agreement [LoA]) and percentage error (PE) at PEEP 0 cm H2 O were 133 mL (-1049 to 1315) and 71%, at PEEP 5 cm H2 O 161 mL (-1291 to 1613 mL) and 66%. In healthy subjects: 21 mL (-755 to 796 mL) and 26%. In porcines, at PEEP 5-20 cm H2 O bias decreased from 223 mL to 136 mL LoA (34-412) to (-30 to 902) and PE 29%-49%. Trending abilities in anaesthetized patients and porcines were 100% concordant. CONCLUSION: The ELV-method showed low bias but high PE in anaesthetized patients. Agreement was good in awake subjects. In porcines, agreement was good at lower PEEP levels. Concordance related to PEEP changes reached 100% in all settings. This method may become a useful trending tool for monitoring lung function during mechanical ventilation, if findings are confirmed in other clinical contexts.


Assuntos
Capnografia/métodos , Pulmão/fisiologia , Respiração com Pressão Positiva , Adulto , Idoso , Animais , Capnografia/estatística & dados numéricos , Feminino , Humanos , Medidas de Volume Pulmonar , Masculino , Pessoa de Meia-Idade , Modelos Animais , Reprodutibilidade dos Testes , Respiração , Suínos , Volume de Ventilação Pulmonar , Adulto Jovem
11.
J Clin Monit Comput ; 34(6): 1199-1207, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31745763

RESUMO

Respiratory failure may cause hemodynamic instability with strain on the right ventricle. The capnodynamic method continuously calculates cardiac output (CO) based on effective pulmonary blood flow (COEPBF) and could provide CO monitoring complementary to mechanical ventilation during surgery and intensive care. The aim of the current study was to evaluate the ability of a revised capnodynamic method, based on short expiratory holds (COEPBFexp), to estimate CO during acute respiratory failure (LI) with high shunt fractions before and after compliance-based lung recruitment. Ten pigs were submitted to lung lavage and subsequent ventilator-induced lung injury. COEPBFexp, without any shunt correction, was compared to a reference method for CO, an ultrasonic flow probe placed around the pulmonary artery trunk (COTS) at (1) baseline in healthy lungs with PEEP 5 cmH2O (HLP5), (2) LI with PEEP 5 cmH2O (LIP5) and (3) LI after lung recruitment and PEEP adjustment (LIPadj). CO changes were enforced during LIP5 and LIPadj to estimate trending. LI resulted in changes in shunt fraction from 0.1 (0.03) to 0.36 (0.1) and restored to 0.09 (0.04) after recruitment manoeuvre. Bias (levels of agreement) and percentage error between COEPBFexp and COTS changed from 0.5 (- 0.5 to 1.5) L/min and 30% at HLP5 to - 0.6 (- 2.3 to 1.1) L/min and 39% during LIP5 and finally 1.1 (- 0.3 to 2.5) L/min and 38% at LIPadj. Concordance during CO changes improved from 87 to 100% after lung recruitment and PEEP adjustment. COEPBFexp could possibly be used for continuous CO monitoring and trending in hemodynamically unstable patients with increased shunt and after recruitment manoeuvre.


Assuntos
Pulmão , Insuficiência Respiratória , Animais , Débito Cardíaco , Humanos , Artéria Pulmonar , Respiração Artificial , Insuficiência Respiratória/terapia , Suínos
12.
BMC Anesthesiol ; 19(1): 28, 2019 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-30808309

RESUMO

BACKGROUND: There is continuing interest among clinicians in the potential for advanced hemodynamic monitoring and "goal directed" intravenous fluid administration guided by minimally-invasive cardiac output measurement to reduce complication rates in high risk patients undergoing major surgery. However, the adoption of the available technologies has been limited, due to cost, complexity and reliability of measurements provided. We review progress in the development of new generation methods for continuous non-invasive monitoring of cardiac output from measurement of carbon dioxide elimination in ventilated patients using the Differential Fick method. MAIN TEXT: The history and underlying theoretical basis are described, and its recent further development and implementation using modern generation anesthesia monitoring and delivery systems by two separate but parallel methods, termed "Capnotracking" and "Capnodynamics". Both methods generate breath-by-breath hands-free cardiac output monitoring from changes in carbon dioxide elimination produced by automatic computerized modulation of respiratory rate delivered by an electronic ventilator. Extensive preclinical validation in animal models of hemodynamic instability, with implanted ultrasonic flow probes for gold standard reference measurements, shows this approach delivers reliable, continuous cardiac output measurement in real time. The accuracy and precision of measurement by the Capnodynamic method were maintained under a wide range of both hemodynamic and respiratory conditions, including inotropic stimulation, vasodilatation, hemorrhage, caval compression, alveolar lavage, changes in tidal volume and positive end-expiratory pressure, and hypercapnia, with only brief derangement observed in a model of lower body ischemia involving release of prolonged aortic occlusion by an intra-aortic balloon. Phase 2 testing of a Capnotracking system in patients undergoing cardiac surgery and liver transplantation has achieved a percentage error of agreement with thermodilution of +/- 38.7% across a wide range of hemodynamic states. CONCLUSIONS: Progress in development of these technologies suggest that a robust, automated and reliable method of non-invasive cardiac output monitoring from capnography is close at hand for use in major surgery and critical care. The great advantage of this approach is that it can be fully integrated into the anesthesia machine and ventilator, using components that are already standard in modern anesthesia and intensive care workstations, and should be virtually hands-free and automatic.


Assuntos
Dióxido de Carbono/metabolismo , Débito Cardíaco/fisiologia , Cuidados Críticos/métodos , Anestesia/métodos , Animais , Capnografia/métodos , Hemodinâmica/fisiologia , Humanos , Reprodutibilidade dos Testes , Respiração Artificial
13.
J Clin Monit Comput ; 30(6): 761-769, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26377022

RESUMO

A capnodynamic calculation of effective pulmonary blood flow includes a lung volume factor (ELV) that has to be estimated to solve the mathematical equation. In previous studies ELV correlated to reference methods for functional residual capacity (FRC). The aim was to evaluate the stability of ELV during significant manipulations of cardiac output (CO) and assess the agreement for absolute values and trending capacity during PEEP changes at different lung conditions. Ten pigs were included. Alterations of alveolar carbon dioxide were induced by cyclic reoccurring inspiratory holds. The Sulphur hexafluoride technique for FRC measurements was used as reference. Cardiac output was altered by preload reduction and inotropic stimulation at PEEP 5 and 12 cmH2O both in normal lung conditions and after repeated lung lavages. ELV at baseline PEEP 5 was [mean (SD)], 810 (163) mL and decreased to 400 (42) mL after lavage. ELV was not significantly affected by CO alterations within the same PEEP level. In relation to FRC the overall bias (limits of agreement) was -35 (-271 to 201) mL, and percentage error 36 %. A small difference between ELV and FRC was seen at PEEP 5 cmH2O before lavage and at PEEP 12 cmH2O after lavage. ELV trending capability between PEEP steps, showed a concordance rate of 100 %. ELV was closely related to FRC and remained stable during significant changes in CO. The trending capability was excellent both before and after surfactant depletion.


Assuntos
Débito Cardíaco/fisiologia , Pulmão/fisiologia , Anestesia , Animais , Capacidade Residual Funcional , Hemodinâmica , Pulmão/irrigação sanguínea , Pulmão/fisiopatologia , Lesão Pulmonar/fisiopatologia , Medidas de Volume Pulmonar , Modelos Teóricos , Respiração com Pressão Positiva/métodos , Valores de Referência , Fluxo Sanguíneo Regional , Testes de Função Respiratória , Hexafluoreto de Enxofre/química , Tensoativos , Suínos , Volume de Ventilação Pulmonar , Fatores de Tempo
14.
J Diabetes Sci Technol ; 8(4): 839-44, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24876424

RESUMO

We have previously shown that intravascular microdialysis in a central vein is an accurate method for continuous glucose monitoring in patients undergoing cardiac surgery. However, no hypoglycemia occurred in our earlier studies, prompting further evaluation of the accuracy of intravascular microdialysis in the hypoglycemic range. Thus, this animal study was performed. A porcine model was developed; hypoglycemia was induced using insulin injections. The pigs were monitored with intravascular microdialysis integrated in a triple-lumen central venous catheter. As reference, venous blood gas samples were taken every 5 minutes and analyzed in a blood gas analyzer. Ethical permission for the animal experiments was obtained from the Stockholm Regional Ethical Committee, reference no N397/09. A total of 213 paired samples were obtained for analysis, and 126 (59.2%) of these were in the hypoglycemic range (<74 mg/dl). Using Clarke error grid analysis, 100% of the paired samples were in region AB and 99% in region A. The ISO standard (ISO15197) was met. Bland-Altman analysis showed bias (mean difference) ± limits of agreement was -0.18 ± 16.2 mg/dl. No influence from glucose infusions was seen. The microdialysis monitoring system was found to be very responsive in rapid changes in blood glucose concentration. This study shows that intravascular microdialysis in a central vein is an accurate method for continuous glucose monitoring in hypoglycemia in a porcine experimental model. Furthermore, the system was not influenced by glucose administration and was found to be responsive in rapid blood glucose fluctuations.


Assuntos
Glicemia/análise , Hipoglicemia/sangue , Microdiálise/métodos , Animais , Vasos Sanguíneos , Catéteres , Hipoglicemiantes/farmacologia , Insulina/farmacologia , Modelos Animais , Suínos , Veia Cava Superior/metabolismo
15.
Anesthesiology ; 119(1): 101-10, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23571638

RESUMO

BACKGROUND: Effective lung volume (ELV) for gas exchange is a new measure that could be used as a real-time guide during controlled mechanical ventilation. The authors established the relationships of ELV to static end-expiratory lung volume (EELV) with varying levels of positive end-expiratory pressure (PEEP) in healthy and surfactant-depleted rabbit lungs. METHODS: Nine rabbits were anesthetized and ventilated with a modified volume-controlled mode where periods of five consecutive alterations in inspiratory/expiratory ratio (1:2-1.5:1) were imposed to measure ELV from the corresponding carbon dioxide elimination traces. EELV and the lung clearance index were concomitantly determined by helium wash-out technique. Airway and tissue mechanics were assessed by using low-frequency forced oscillations. Measurements were collected at PEEP 0, 3, 6, and 9 cm H2O levels under control condition and after surfactant depletion by whole-lung lavage. RESULTS: ELV was greater than EELV at all PEEP levels before lavage, whereas there was no evidence for a difference in the lung volume indices after surfactant depletion at PEEP 6 or 9 cm H2O. Increasing PEEP level caused significant parallel increases in both ELV and EELV levels, decreases in ventilation heterogeneity, and improvement in airway and tissue mechanics under control condition and after surfactant depletion. ELV and EELV exhibited strong and statistically significant correlations before (r=0.84) and after lavage (r=0.87). CONCLUSIONS: The parallel changes in ELV and EELV with PEEP in healthy and surfactant-depleted lungs support the clinical value of ELV measurement as a bedside tool to estimate dynamic changes in EELV in children and infants.


Assuntos
Medidas de Volume Pulmonar , Pulmão/fisiologia , Troca Gasosa Pulmonar/fisiologia , Surfactantes Pulmonares/metabolismo , Algoritmos , Análise de Variância , Animais , Hélio , Hemodinâmica/fisiologia , Depuração Mucociliar , Coelhos , Testes de Função Respiratória , Mecânica Respiratória/fisiologia
16.
Nutr Metab (Lond) ; 4: 2, 2007 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-17212815

RESUMO

BACKGROUND: Surgery, commonly performed after an overnight fast, causes a postoperative decline in the anabolic and glucose lowering insulin-like growth factor-1 (IGF-1). Clinical fasting studies have exhibited a positive correlation between IGF-1 and nitrogen balance during different conditions. A perioperative amino acid infusion changes nitrogen balance and might thereby influence serum IGF-1. We hypothesized that amino acid infusion would enhance IGF-1 and thereby might influence glucose homeostasis after surgery. In this study we examined two different regimes of perioperative amino acids infusion. METHODS: 24 females scheduled for abdominal hysterectomy were randomized into three groups; Ringer's solution infusion throughout anesthesia (Group B), amino acid infusion throughout anesthesia (Group C) and amino acid infusion 1 hour before anesthesia and during 1.5 hrs of surgery (Group D). Six female volunteers, who were not operated, but received the same amino acids infusion after fasting, served as controls (Group A). Fasting levels of IGF-1, Insulin-like growth factor binding protein-1 (IGFBP-1), insulin and P-glucose were studied prior to, and four days following, operation. Homeostasis model assessment (HOMA) was used as an index of insulin resistance. Non-parametric statistical methods were used. RESULTS: During the study the Ringer-group exhibited a decrease in IGF-1 and an increase in insulin and plasma glucose after surgery. Within the other groups there were no significant alterations over time after surgery, with the exception of a postoperative decrease in IGF-1 in group D. Group C had higher IGF-1 levels compared to group B on all days. Also, group D had higher IGF-1 levels than group B on day 2-4. From baseline to the first postoperative day there was a significant increase in HOMA and IGFBP-1 in groups B and C. These changes were not found in group D, in which insulin, glucose, HOMA and IGFBP-1 did not change. Amino acid infusion to the volunteers did not affect any of the variables studied. CONCLUSION: Amino acid infusion during surgery attenuates the decrease in IGF-1 and diminishes the "diabetes of injury".

17.
Phys Rev E Stat Nonlin Soft Matter Phys ; 74(2 Pt 1): 021908, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17025473

RESUMO

The motility of certain gram-negative bacteria is mediated by retraction of type IV pili surface filaments, which are essential for infectivity. The retraction is powered by a strong molecular motor protein, PilT, producing very high forces that can exceed 150 pN. The molecular details of the motor mechanism are still largely unknown, while other features have been identified, such as the ring-shaped protein structure of the PilT motor. The surprisingly high forces generated by the PilT system motivate a model investigation of the generation of large forces in molecular motors. We propose a simple model, involving a small ensemble of motor subunits interacting through the deformations on a circular backbone with finite stiffness. The model describes the motor subunits in terms of diffusing particles in an asymmetric, time-dependent binding potential (flashing ratchet potential), roughly corresponding to the ATP hydrolysis cycle. We compute force-velocity relations in a subset of the parameter space and explore how the maximum force (stall force) is determined by stiffness, binding strength, ensemble size, and degree of asymmetry. We identify two qualitatively different regimes of operation depending on the relation between ensemble size and asymmetry. In the transition between these two regimes, the stall force depends nonlinearly on the number of motor subunits. Compared to its constituents without interactions, we find higher efficiency and qualitatively different force-velocity relations. The model captures several of the qualitative features obtained in experiments on pilus retraction forces, such as roughly constant velocity at low applied forces and insensitivity in the stall force to changes in the ATP concentration.


Assuntos
Adenosina Trifosfatases/fisiologia , Adenosina Trifosfatases/ultraestrutura , Proteínas de Bactérias/fisiologia , Proteínas de Bactérias/ultraestrutura , Modelos Biológicos , Modelos Químicos , Proteínas Motores Moleculares/química , Proteínas Motores Moleculares/fisiologia , Simulação por Computador , Difusão , Modelos Estatísticos , Proteínas Motores Moleculares/ultraestrutura , Movimento (Física) , Estresse Mecânico
18.
Anesth Analg ; 98(3): 763-7, table of contents, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-14980934

RESUMO

UNLABELLED: In today's intensive care and surgery, a great number of cables are attached to patients. These cables can make the care and nursing of the patient difficult. Replacing them with wireless communications technology would facilitate patient care. Bluetooth is a modern radio technology developed specifically to replace cables between different pieces of communications equipment. In this study we sought to determine whether Bluetooth is a suitable replacement for cables in intensive care and during surgery with respect to electromagnetic compatibility. The following questions were addressed: Does Bluetooth interfere with medical equipment? And does the medical equipment decrease the quality of the Bluetooth communication? A Bluetooth link, simulating a patient monitoring system, was constructed with two laptops. The prototype was then used in laboratory and clinical tests according to American standards at the Karolinska Hospital in Stockholm. The tests, which included 44 different pieces of medical equipment, indicated that Bluetooth does not cause any interference. The tests also showed that the hospital environment does not affect the Bluetooth communication negatively. IMPLICATIONS: Bluetooth, a new radio technology transmitting at 2.4 GHz, was tested in a clinical setting. The study showed that a single Bluetooth link was robust and electromagnetically compatible with the tested electronic medical devices.


Assuntos
Cuidados Críticos , Monitorização Intraoperatória/instrumentação , Software , Procedimentos Cirúrgicos Operatórios , Telecomunicações/instrumentação , Redes de Comunicação de Computadores , Equipamentos e Provisões , Unidades de Terapia Intensiva/organização & administração , Monitorização Intraoperatória/efeitos adversos , Salas Cirúrgicas/organização & administração
19.
J Cardiothorac Vasc Anesth ; 17(4): 470-7, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12968235

RESUMO

OBJECTIVES: To investigate the influence of glucose-insulin-potassium (GIK) on the growth hormone/insulin-like growth factor-1 axis. DESIGN: Randomized clinical study. SETTING: University hospital. PARTICIPANTS: Twenty patients, without metabolic disorders, admitted for elective aortocoronary bypass surgery. INTERVENTIONS: GIK therapy. Measurements and main results Blood samples were taken repeatedly during the day of surgery. Ejection fraction (EF) was determined by transesophageal echocardiography before and at the end of surgery. Blood samples were taken on the first postoperative day and at discharge (8 am and 8 pm). During coronary artery bypass graft (CABG) surgery, a rapid decrease (44%) in total IGF-1 occurred in both groups. Directly after cessation of extracorporeal circulation, there was a prompt rise in IGFBP-1. The mean peak value in the control group was more than 3 times higher than in the GIK group. GH secretion was stimulated by surgery in both groups and was enhanced by GIK. B-glucose was significantly higher in the control group during surgery. EF ( approximately 55% at baseline) was unchanged in both groups. Postoperatively, there were no differences between the groups (all parameters). At discharge, IGFBP-1 was unchanged, but insulin was elevated compared with preoperative levels. This was seen in both groups, reflecting a hepatic insulin resistance. Conclusions The authors conclude that GIK blunts the rise of IGFBP-1 and thereby increases the bioavailability of IGF-1. GIK also seems to speed up the return of IGF-1 to baseline. Both mechanisms could be of importance to catabolic high-risk patients with low IGF-1. Hence, GIK has favorable effects on the GH/IGF-1 axis during CABG surgery.


Assuntos
Ponte de Artéria Coronária , Glucose/uso terapêutico , Hormônio do Crescimento/efeitos dos fármacos , Proteínas de Ligação a Fator de Crescimento Semelhante a Insulina/efeitos dos fármacos , Fator de Crescimento Insulin-Like I/efeitos dos fármacos , Insulina/uso terapêutico , Cuidados Intraoperatórios , Potássio/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Glicemia/efeitos dos fármacos , Glicemia/metabolismo , Nitrogênio da Ureia Sanguínea , Circulação Extracorpórea , Feminino , Hormônio do Crescimento/metabolismo , Hemoglobinas/efeitos dos fármacos , Hemoglobinas/metabolismo , Humanos , Insulina/sangue , Proteínas de Ligação a Fator de Crescimento Semelhante a Insulina/metabolismo , Fator de Crescimento Insulin-Like I/metabolismo , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Estatística como Assunto , Volume Sistólico/efeitos dos fármacos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA